PHILOS plate fixation with polymethyl methacrylate cement augmentation of an osteoporotic proximal humerus fracture.

Kim, Do-Young; Kim, Tae-Yeong; Hwang, Jung-Taek · Clin Shoulder Elb · 2020

case_report · Level V

Where this comes from

Abstract

PHILOS plate fixation in osteoporotic proximal humerus fracture of old age is well-known for high complication rate, especially metal failure, providing various augmentation techniques, such as calcium phosphate cement, allogenous or autologous bone graft. We report a case of polymethyl methacrylate augmentation to provide appropriate reduction with a significant mechanical support. This can be a treatment option for displaced unstable osteoporotic proximal humerus fracture with marked bony defect.

Anatomy