Diastolic Function and Clinical Outcomes After Transcatheter Aortic Valve Replacement: PARTNER 2 SAPIEN 3 Registry.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 33334422.
- Also identified by DOI 10.1016/j.jacc.2020.10.032.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Few studies have evaluated if diastolic function could predict outcomes in patients with aortic stenosis. The authors aimed to assess the association between diastolic dysfunction (DD) and outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). Baseline, 30-day, and 1- and 2-year transthoracic echocardiograms from the PARTNER (Placement of Aortic Transcatheter Valves) 2 SAPIEN 3 registry were analyzed by a consortium of core laboratories and divided into the American Society of Echocardiography DD groups. Among the 1,750 included, 682 (54.4%) had grade 1 DD, 352 (28.1%) had grade 2 DD, 168 (13.4%) had grade 3 DD, and 51 (4.1%) had indeterminate DD grade. Incremental baseline grades of DD were associated with an increase in combined 1- and 2-year cardiovascular (CV) death/rehospitalization (all p < 0.002) and all-cause death at 2 years (p = 0.01) but not at 1 year. Improvement in DD grade/grade 1 DD at 30 days post-TAVR was seen in 70.8% patients. Patients with improvement in ≥1 grade of DD/grade 1 DD had reduced 1-year CV death/rehospitalization (p < 0.001) and increased 2-year survival (p = 0.01). Baseline grade 3 DD was a predictor of 1-year CV death/rehospitalization (hazard ratio: 2.73; 95% confidence interval: 1.07 to 6.98; p = 0.04). Improvement in DD grade/grade 1 DD at 30 days was protective for 1-year CV death/rehospitalizations (hazard ratio: 0.39; 95% confidence interval: 0.19 to 0.83; p = 0.01). In the PARTNER 2 SAPIEN 3 registry, baseline DD was a predictor of up to 2 years clinical outcomes in patients who underwent TAVR. Improvement in DD grade at 30 days was associated with improvement in short-term clinical outcomes. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - PARTNER II - PARTNERII - S3 Intermediate [PARTNERII S3i]; NCT03222128; PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - High Risk and Nested Registry 7 [PII S3HR/NR7]; NCT03222141).
Medical subject headings
- Aortic Valve Stenosis
- Heart Failure, Diastolic
- Patient Readmission
- Postoperative Complications
- Transcatheter Aortic Valve Replacement