Abstract
This study aimed to examine the accuracy of the HipAlign® accelerometer-based portable navigation system by measuring the intraoperative leg length change of patients who underwent total hip arthroplasty (THA) and comparing the measured leg length discrepancy (LLD) determined by the navigation system and a freehand technique. A total of 61 patients who underwent THA using the anterolateral approach in the supine position were included in this study and divided into two groups: those who underwent THA with navigation (Group N; N = 31) and with the freehand technique (Group F; N = 30). Statistical analyses were performed to compare the intraoperative leg length change, pre- and post-LLD, absolute values of post-LLD, and the number of patients with the postoperative LLD within 10 mm and 5 mm between the two groups. Additionally, we examined the correlation between the leg length change obtained through intraoperative navigation and measured from the radiographs. Moreover, to evaluate the navigation accuracy, we examined the correlation between the absolute error of leg length change and cup orientation. The postoperative LLD was significantly lower and the number of patients with the postoperative LLD within 5 mm was significantly higher in Group N, compared with Group F. Additionally, the amount of leg length change measured intraoperatively by the navigation system was strongly correlated with the values obtained by the postoperative radiographic measurement with a small absolute error and minimal wasted time. Moreover, a significant positive correlation was found between the absolute error of the leg length change and that of the cup inclination. Our study demonstrates that the accelerometer-based portable navigation system is useful for the intraoperative adjustment of leg length discrepancy during THA for patients in the supine position, as it provides good accuracy and minimizes required time for use.
Medical subject headings
- Arthroplasty, Replacement, Hip
Anatomy
- hip