Sudden Tamponade From Vein Graft Side Branch Avulsion on Removal of Temporary Pacemaker Wires.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 33412142.
- Also identified by DOI 10.1016/j.athoracsur.2020.10.060.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Temporary epicardial pacing wires are universally used in cardiac surgery and are associated with very low morbidity and mortality. Although rare, serious complications can occur with pacing wires. We present a case of avulsion of a saphenous vein graft side branch caused by removal of pacing wires and leading to pericardial tamponade. Our case favors the use of silk ties rather than hemoclips for occlusion of saphenous vein side branches and illustrates the importance of the location of pacing wires relative to the grafts at the time of coronary artery bypass surgery.
Medical subject headings
- Cardiac Surgical Procedures
- Cardiac Tamponade
- Pacemaker, Artificial
- Postoperative Complications