Accuracy of intraoperative estimation of femoral stem anteversion in cementless total hip arthroplasty by using a digital protractor and a spirit level.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 33413529.
- Also identified by DOI 10.1186/s13018-020-02183-7 and PMC identifier 7792124.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
The femoral component anteversion during surgery is traditionally assessed by a visual assessment of the surgeon and has proven to be imprecise. We sought to determine the accuracy of a digital protractor and a spirit level to measure the stem anteversion during cementless THA. A prospective study was conducted among 107 patients (114 hips) who underwent primary cementless THA via posterolateral approach. A pipe with a spirit level was attached to the tibial tubercle and intermalleolar midpoint. While the leg was held perpendicularly to the floor, stem anteversion was estimated by 3 methods: method A by visual assessment; method B by a digital protractor alone; and method C by a digital protractor combined with a spirit level. The angles were compared with the true anteversion measured by postoperative CT scan. The average anteversion by method C (22.8° ± 6.9°, range -2° to 40°) was significantly lower than method A (24.6° ± 5.2°, range 0° to 30°) (p=0.033), but not different from the true anteversion (22.1° ± 8.2°, range -5.4° to 43.1°) (p=0.445). There were no significant differences between method B (23.2° ± 8.2°, range -4° to 45°) and method A, C or the true anteversion. The mean deviation of the intraoperative estimation from the true anteversion was 0.8° ± 3.7° (range -7.1° to 8.0°) by method C; 1.2° ± 5.1° (range -8.8° to 14.3°) by method B; and 2.5° ± 7.4° (range -19.0° to 16.0°) by method A. Estimation error within 5° was found in 107 hips (93.9%) with method C; 86 hips (75.4%) with method B; and 59 hips (51.8%) with method A. Accurate estimation of stem anteversion during cementless THA can be determined intraoperatively by the use of a digital protractor and a spirit level. Thai Clinical Trials Registry ( TCTR 20180326003 ). Registered on 20 March 2018. Retrospectively registered.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Bone Anteversion
- Femur
- Hip Prosthesis
- Prosthesis Fitting
Anatomy
- femur
- hip