Accuracy of Fibula Reconstruction Using Patient-Specific Cad/Cam Plates: A Multicenter Study on 47 Patients.

Zavattero, Emanuele; Bolzoni, Alessandro; Dell'Aversana, Giovanni; Santagata, Mario; Massarelli, Olindo; Ferri, Andrea; Della Monaca, Marco; Copelli, Chiara et al. · Laryngoscope · 2021

prospective_cohort · Level II

Where this comes from

Abstract

This prospective study evaluated the accuracy of mandibular reconstruction using free fibular flaps (by comparing virtual plans to the three-dimensional postoperative results), and the extent of bone-to-bone contact after computer-assisted surgery. We included 65 patients who underwent partial-continuity mandibular resections from February 2013 to January 2017, and evaluated virtual planning, surgical techniques, and accuracy. Forty-seven patients were analysed. A total of 112 fibular segments received 54 implants. We measured 227 distances between landmarks to assess the accuracy of reconstruction. Postoperative reconstruction accuracy ranged from 0.5 to 3 mm. Virtual surgical planning very accurately translated simulation into reality, particularly in patients requiring large, complex mandibular reconstructions using multiple fibular segments. 4 Laryngoscope, 131:E2169-E2175, 2021.