Ultrasound-Guided Biceps Tendon Sheath Injections Frequently Extravasate Into the Glenohumeral Joint.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 33453348.
- Also identified by DOI 10.1016/j.arthro.2020.12.238.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate the frequency of glenohumeral joint extravasation of ultrasound (US)-guided biceps tendon sheath injections. Fifty shoulders with a clinical diagnosis of bicipital tenosynovitis pain received a US-guided biceps sheath injection with anesthetic, steroid, and contrast (5.0 mL mixture) followed immediately by orthogonal radiographs to localize the anatomic distribution of the injection. Radiographic evaluation of contrast localization was determined and interobserver reliability calculated. All 50 postinjection radiographs (100%) demonstrated contrast within the biceps tendon sheath. In addition, 30 of 50 (60%) radiographs also revealed contrast in the glenohumeral joint. Interobserver reliability for determination of intraarticular contrast was good (kappa value 0.87). US-guided bicipital sheath injections reproducibly result in intrasheath placement of injection fluid. Bicipital sheath injections performed with 5 mL of volume result in partial extravasation into the joint 60% of the time. These data may be useful for surgeons who use the results of diagnostic biceps injections for diagnosis and surgical decision-making. III, prospective cohort study, diagnosis.