Quantitative susceptibility-weighted imaging may be an accurate method for determining stroke hypoperfusion and hypoxia of penumbra.
Where this comes from
- Record sourced from PubMed, PMID 33512568.
- Also identified by DOI 10.1007/s00330-020-07485-2.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To quantitatively evaluate the volume of the ischemic penumbra using susceptibility-weighted imaging and mapping (SWIM) of asymmetrical prominent cortical veins (APCVs) in patients with acute ischemic stroke. Eighty-five eligible patients with acute ischemic stroke on admission within 12 h from symptom onset were studied. The APCVs on SWIM were quantitatively (SWI-volume) and semi-quantitatively (SWI-Alberta Stroke Program Early CT Score, SWI-ASPECTS) evaluated to calculate mismatch. To assess the diagnostic efficacy of APCVs on SWIM, comparative analyses were performed between SWI<sub>volume</sub>-DWI mismatch and SWI<sub>ASPECTS</sub>-DWI mismatch, using PWI-DWI mismatch as a reference. Correlations were calculated between the mismatches, as well as between SWI-volume and time-to-maximum (Tmax) > 6 s volume. Additionally, each of these mismatches was correlated with the National Institute of Health Stroke Scale (NIHSS). The sensitivity, negative predictive value, and accuracy of SWI<sub>volume</sub>-DWI mismatch were demonstrably higher than SWI<sub>ASPECTS</sub>-DWI mismatch (100% vs. 53.7%, 100% vs. 9.5%, 97.7% vs. 54.5%, respectively). A significant positive correlation was found between SWI<sub>volume</sub>-DWI and PWI-DWI mismatch (r = 0.691, p < 0.01), as well as between SWI-volume and Tmax > 6 s volume (r = 0.786, p < 0.001). A significant negative correlation was found between SWI<sub>volume</sub>-DWI mismatch and NIHSS (r = - 0.360, p = 0.022), as well as between SWI<sub>ASPECTS</sub>-DWI mismatch and NIHSS (r = - 0.499, p = 0.001). SWI<sub>volume</sub>-DWI mismatch had higher diagnostic efficacy than SWI<sub>ASPECTS</sub>-DWI mismatch in defining the ischemic penumbra and showed good consistency with PWI-DWI mismatch in acute ischemic stroke. Quantitation of APCVs using SWIM provided an accurate method for determining hypoperfusion and provided a reliable method to reflect the hypoxia of penumbra. • SWI<sub>volume</sub>-DWI mismatch has higher diagnostic efficacy than SWI<sub>ASPECTS</sub>-DWI mismatch in defining the ischemic penumbra. • SWI<sub>volume</sub>-DWI mismatch shows good consistency with PWI-DWI mismatch in managing penumbra in acute ischemic stroke. • Quantitation of APCV volume using SWIM provided an accurate method for determining the hypoperfusion area and provided a reliable method to reflect the hypoxia of penumbra.
Medical subject headings
- Brain Ischemia
- Stroke