Adequacy of Unenhanced MRI for Surveillance of Small (Clinical T1a) Solid Renal Masses.

Mawi, Hatem; Narine, Rishi; Schieda, Nicola · AJR Am J Roentgenol · 2021

retrospective_cohort · Level III

Where this comes from

Abstract

<b>OBJECTIVE.</b> The purpose of this study was to determine if contrast enhancement is necessary for MRI surveillance of clinical T1a (cT1a) solid renal masses. <b>MATERIALS AND METHODS.</b> With institutional review board approval, 36 patients who underwent two or more contrast-enhanced (CE) MRI examinations (median, four examinations; range, two to 10 examinations) for surveillance of 39 cT1a solid renal masses between 2009 and 2019 (median time between scans, 2 years; range, 1-7 years) were evaluated. Two radiologists independently measured renal mass size and assessed tumor stage in two sessions for baseline and follow-up examinations using T1-weighted nephrographic phase CE-MRI and unenhanced single-shot T2-weighted MRI in mixed order with a 4-week washout period. Comparisons were performed using the Wilcoxon sign-rank test and Pearson correlation. Bland-Altman and intraclass correlation determined interobserver agreement. <b>RESULTS.</b> Mean size ± SD of renal masses on CE-MRI and T2-weighted MRI were 18 ± 5 mm (range, 9-37 mm) and 18 ± 5 mm (range, 9-37 mm) for radiologist 1 and 19 ± 7 mm (range, 10-39 mm) and 19 ± 6 mm (range, 10-39 mm) for radiologist 2 with near perfect correlation (for radiologist 1, β = 0.9897; for radiologist 2, β = 0.9317; <i>p</i> < .001). Interob-server agreement for measurements comparing radiologist 1 and radiologist 2 on CEMRI and T2-weighted MRI and intraobserver agreement for measurements on CE-MRI and T2-weighted MRI were excellent. Mean growth rate of renal masses measured on CE-MRI and T2-weighted MRI were 2 ± 2 mm (range, -5 to 8 mm) and 2 ± 3 mm (range, -3 to 8 mm) for radiologist 1 and 3 ± 5 mm (range, -1 to 18 mm) and 3 ± 6 mm (range, -1 to 24 mm) for radiologist 2 with high correlation (for radiologist 1, β = 0.8313 [<i>p</i> < .001]; for radiologist 2, β = 0.848 [<i>p</i> = .002]). At baseline, all tumors were subjectively cT1a on CE-MRI and T2-weighted MRI (<i>p</i> > .99, intraclass correlation coefficient [ICC] = 1). During follow-up, one mass progressed to T3 on CE-MRI and T2-weighted MRI for radiologist 1 and radiologist 2 (<i>p</i> > .99, ICC = 1). <b>CONCLUSION.</b> In this study, size measurements on unenhanced T2-weighted MRI had near perfect correlation to measurements using CE-MRI in cT1a solid renal masses undergoing surveillance, with high agreement between and within observers. Clinical staging did not differ comparing T2-weighted MRI and CE-MRI, with near perfect agreement. Contrast enhancement is not necessary for follow-up size measurements in cT1a solid renal masses with MRI.

Medical subject headings