Dynamic MRI Reconstruction via Weighted Tensor Nuclear Norm Regularizer.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 33625992.
- Also identified by DOI 10.1109/JBHI.2021.3061793.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In this paper, we propose a novel multi-dimensional reconstruction method based on the low-rank plus sparse tensor (L+S) decomposition model to reconstruct dynamic magnetic resonance imaging (dMRI). The multi-dimensional reconstruction method is formulated using a non-convex alternating direction method of multipliers (ADMM), where the weighted tensor nuclear norm (WTNN) and l<sub>1</sub>-norm are used to enforce the low-rank in L and the sparsity in S, respectively. In particular, the weights used in the WTNN are sorted in a non-descending order, and we obtain a closed-form optimal solution of the WTNN minimization problem. The theoretical properties provided guarantee the weak convergence of our reconstruction method. In addition, a fast inexact reconstruction method is proposed to increase imaging speed and efficiency. Experimental results demonstrate that both of our reconstruction methods can achieve higher reconstruction quality than the state-of-the-art reconstruction methods.
Medical subject headings
- Algorithms
- Magnetic Resonance Imaging