Glycemic Outcome Associated With Insulin Pump and Glucose Sensor Use in Children and Adolescents With Type 1 Diabetes. Data From the International Pediatric Registry SWEET.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 33653821.
- Also identified by DOI 10.2337/dc20-1674.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Insulin delivery methods, glucose-monitoring modalities, and related outcomes were examined in a large, international, diverse cohort of children and adolescents with type 1 diabetes from the Better Control in Pediatric and Adolescent Diabetes: Working to Create Centers of Reference (SWEET) -Registry. Participants with type 1 diabetes of ≥1 year, aged ≤18 years, and who had documented pump or sensor usage during the period August 2017-July 2019 were stratified into four categories: injections-no sensor (referent); injections + sensor; pump-no sensor; and pump + sensor. HbA<sub>1c</sub> and proportion of patients with diabetic ketoacidosis (DKA) or severe hypoglycemia (SH) were analyzed; linear and logistic regression models adjusted for demographics, region, and gross domestic product per capita were applied. Data of 25,654 participants were analyzed. The proportions of participants (adjusted HbA<sub>1c</sub> data) by study group were as follows: injections-no sensor group, 37.44% (8.72; 95% CI 8.68-8.75); injections + sensor group, 14.98% (8.30; 95% CI 8.25-8.35); pump-no sensor group, 17.22% (8.07; 95% CI 8.03-8.12); and pump + sensor group, 30.35% (7.81; 95% CI 7.77-7.84). HbA<sub>1c</sub> was lower in all categories of participants who used a pump and/or sensor compared with the injections-no sensor treatment method (<i>P</i> < 0.001). The proportion of DKA episodes was lower in participants in the pump + sensor (1.98%; 95% CI 1.64-2.48; <i>P</i> < 0.001) and the pump-no sensor (2.02%; 95% CI 1.64-2.48; <i>P</i> < 0.05) groups when compared with those in the injections-no sensor group (2.91%; 95% CI 2.59-3.31). The proportion of participants experiencing SH was lower in pump-no sensor group (1.10%; 95% CI 0.85-1.43; <i>P</i> < 0.001) but higher in the injections + sensor group (4.25%; 95% CI 3.65-4.95; <i>P</i> < 0.001) compared with the injections-no sensor group (2.35%; 95% CI 2.04-2.71). Lower HbA<sub>1c</sub> and fewer DKA episodes were observed in participants using either a pump or continuous glucose monitoring (CGM) or both. Pump use was associated with a lower rate of SH. Across SWEET centers, use of pumps and CGM is increasing. The concomitant use of pump and CGM was associated with an additive benefit.
Medical subject headings
- Diabetes Mellitus, Type 1