Estimated cumulative X-ray exposure and additional cancer risk during the evaluation and treatment of scoliosis in children and young people requiring surgery.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 33660241.
- Also identified by DOI 10.1007/s43390-021-00314-6 and PMC identifier 8270816.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
Clinicians and patients must weigh the benefits of radiological imaging against the risks of radiation exposure in the diagnosis and treatment of scoliosis. This report aims to estimate the cumulative absorbed and equivalent dose of radiation in patients undergoing surgical treatment for scoliosis, and to present this as an estimated risk of cancer compared to background radiation levels. Retrospective review of estimated absorbed dose on the Computerised Radiology Information System (CRIS<sup>®</sup>). Patients undergoing surgical correction of scoliosis (age ≤ 25) from August 2010 to August 2015 investigated. Estimated absorbed dose [milligrays (mGy)] recorded. Pedicle screws inserted using image intensification. Equivalent dose [millisieverts (mSv)] and additional cancer risk calculated from the National Research Council document 'Health risks from exposure to low levels of ionising radiation' (2006). 271 patients identified. Mean age 15 (range 2-25). Mean total absorbed dose 2136 mGy [standard deviation (SD) 1700 mGy]. Mean number of plain spine radiographs was 8 (SD 3) with total 1884 mGy exposure (SD 1609 mGy). Additional dose provided by CT (mean 0.17 episodes), plain chest and abdominal radiographs and image intensification. Mean number of image intensification episodes was 1.1 with mean estimated exposure 180 mGy (SD 238 mGy). Image intensification accounted for 8% of the estimated absorbed dose during treatment. Estimated mean effective dose delivered was 20.952 mSv equating to an additional cancer risk of 0.27-0.45%. Additional cancer risk from cumulative imaging is small and equivalent to approximately 8 years of natural background radiation. Use of image intensification for pedicle screw insertion is a minor contribution (8%) to the total patient dose.
Medical subject headings
- Neoplasms
- Scoliosis