The effect of four-corner fusion and proximal row carpectomy on uniplanar and multiplanar wrist motion: A biomechanical study.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 33679035.
- Also identified by DOI 10.1016/j.jor.2021.02.032 and PMC identifier 7930352.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To compare changes in wrist kinematics after scaphoidectomy and four-corner fusion (4CF), and proximal row carpectomy (PRC). Six cadaveric specimens underwent flexion-extension, radial-ulnar deviation and circumduction in an active motion wrist simulator. Native state, "anatomic 4CF", "radial 4CF", and PRC were compared. Radial 4CF reduced wrist extension, while PRC reduced radial deviation. Fusion groups had similar motion profiles. 44%, 41%, and 32% of native circumduction was maintained in PRC, anatomic, and radial 4CF. Both fusion positions resulted in comparable motion outcomes. Anatomic 4CF was restricted in wrist extension compared to PRC but provided favourable radial deviation.
Anatomy
- wrist