A Y Incision and Rectangular Patch to Enlarge the Aortic Annulus by Three Valve Sizes.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 33684349.
- Also identified by DOI 10.1016/j.athoracsur.2021.01.072 and PMC identifier 8316270.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
For a fifth-time redo aortic valve replacement, a Y incision was made through the left-noncommissure post into the aortomitral curtain above the mitral annulus, undermining the aortic annulus below the nadirs of left coronary and noncoronary cusps without violating the left atrium or mitral valve. A rectangular Hemashield (Maquet Cardiovascular, San Jose, CA) patch was used to extensively enlarge the aortomitral curtain. The aortic annulus was increased from 21 mm to 27 mm for a mechanical aortic valve replacement. The patient was discharged without blood transfusion or any complications. Our enlargement technique was simple and effective to enlarge the aortic annulus for mechanical aortic valve replacement.
Medical subject headings
- Aortic Valve
- Aortic Valve Stenosis
- Bioprosthesis
- Transcatheter Aortic Valve Replacement