Cryo-EM is a powerful tool, but helical applications can have pitfalls.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 33729271.
- Also identified by DOI 10.1039/d1sm00282a and PMC identifier 8086904.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In structural biology, cryo-electron microscopy (cryo-EM) has emerged as the main technique for determining the atomic structures of macromolecular complexes. This has largely been due to the introduction of direct electron detectors, which have allowed for routinely reaching a near-atomic resolution when imaging such complexes. In chemistry and materials science, the applications of cryo-EM have been much more limited. A recent paper (Z. Li et al., Chemically Controlled Helical Polymorphism In Protein Tubes By Selective Modulation Of Supramolecular Interactions, J. Am. Chem. Soc. 2019, 141, 19448-19457) has used low resolution cryo-EM to analyze polymorphic helical tubes formed by a tetrameric protein, and has made detailed models for the interfaces between the tetramers in these assemblies. Due to intrinsic ambiguities in determining the correct helical symmetry, we show that many of the models are likely to be wrong. This note highlights both the enormous potential for using cryo-EM, and also the pitfalls possible for helical assemblies when a near-atomic level of resolution is not reached.