Dual-mobility bearings in complex revision hip arthroplasty.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 33736488.
- Also identified by DOI 10.1177/1120700021999795.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Revision total hip arthroplasty (rTHA) is associated with an increased dislocation risk. Dual-mobility (DM) bearings have been used to address this issue. Such constructs offer increased range of motion and enhanced stability whilst avoiding some issues associated with fully-constrained devices. DM bearings have been used in our unit since 2013. All rTHA cases since 2013 were reviewed using the following criteria: (1) use of a DM bearing; (2) extensive soft tissue or bone loss resulting from ARMD, infection or multiple revisions, or requiring custom or megaprosthetic reconstruction; (3) minimum 2-month follow-up. 52 cases were identified with a median of 2 previous operations (range 1-6) and mean follow-up of 14 (2-41) months. The Novae-Stick component was used in 50 cases, the Avantage in 2 and the Trident MDM in 1 case. 19 required acetabular reconstruction using trabecular metal and four required custom acetabular components. 19 required femoral reconstruction with a proximal or total femoral replacement.Postoperatively, 8 patients (15.4%) sustained a dislocation at a mean of 1.6 (range 1-3) months. 3 (5.8%) requiring re-revision. 1 required excision arthroplasty and 2 a constrained liner, 1 of which went on to have further instability. There were no intraprosthetic dislocations. Dual-mobility components are a viable option in the complex rTHA setting. Early dislocations can occur but the rate of instability is acceptable in this high-risk group.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Dislocation
- Hip Prosthesis
- Joint Dislocations
Anatomy
- hip
- pelvis