Full-Thickness Radial Medial Meniscal Tear: Fixation With Inside-Out Technique With Tibial Knotless Suture Anchors.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 33738222.
- Also identified by DOI 10.1016/j.eats.2020.10.075 and PMC identifier 7953262.
- Licence recorded as CC BY-NC-ND.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Complete radial tears of the meniscus render the entirety of the meniscus functionally incompetent (known as an ameniscal state); therefore, attempts at repair are essential. Although various techniques have been described, repair failures continue to frequently occur, especially with the medial meniscus. Inside-out repair and anchoring of the preserved meniscus to both the capsule and tibia may offer the advantage of a more robust repair. The objective of this Technical Note is to describe a method of repair for complete radial tears of the medial meniscus using a combination of inside-out sutures and secondary reinforcement to the tibia using all-suture knotless anchors.
Anatomy
- tibia