Sutureless Patch Repair With a Novel Adhesive for Postinfarction Ventricular Septal Rupture.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 33794161.
- Also identified by DOI 10.1016/j.athoracsur.2021.03.051.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Ventricular septal rupture after acute myocardial infarction is a fatal complication with a very high in-hospital mortality. Herein, we describe a new repair technique using a first patch for exclusion of the infarcted myocardium and a second sutureless patch for rupture site closure with a novel tissue adhesive (Hydrofit, Terumo, Tokyo, Japan). Follow-up of over 2 years revealed a good clinical course and no residual interventricular shunt on echocardiography. This modified infarct exclusion technique with a second sutureless patch has a benefit of avoiding stitches to the fragile infarcted myocardium and might be effective in preventing interventricular shunt recurrence after ventricular septal rupture.
Medical subject headings
- Sutureless Surgical Procedures
- Tissue Adhesives
- Ventricular Septal Rupture