<sup>68</sup>Ga-PSMA-11 PET, <sup>18</sup>F-PSMA-1007 PET, and MRI for Gross Tumor Volume Delineation in Primary Prostate Cancer: Intermodality and Intertracer Variability.

Draulans, Cédric; Pos, Floris; Smeenk, Robert J; Kerkmeijer, Linda; Vogel, Wouter V; Nagarajah, James; Janssen, Marcel; Mai, Cindy et al. · Pract Radiat Oncol · 2021

prospective_cohort · Level II

Where this comes from

Abstract

To assess the intermodality and intertracer variability of gallium-68 (<sup>68</sup>Ga)- or fluorine-18 (<sup>18</sup>F)-labeled prostate-specific membrane antigen (PSMA) positron emission tomography (PET) and biparametric magnetic resonance imaging (bpMRI)-based gross tumor volume (GTV) delineation for focal boosting in primary prostate cancer. Nineteen prospectively enrolled patients with prostate cancer underwent a PSMA PET/MRI scan, divided into a 1:1 ratio between <sup>68</sup>Ga-PSMA-11 and <sup>18</sup>F-PSMA-1007, before radical prostatectomy (IWT140193). Four delineation teams performed manual contouring of the GTV based on bpMRI and PSMA PET imaging, separately. Index lesion coverage (overlap%) and interobserver variability were assessed. Furthermore, the distribution of the voxelwise normalized standardized uptake values (SUV%) was determined for the majority-voted (>50%) GTV (GTV<sup>majority</sup>) and whole prostate gland to investigate intertracer variability. The median patientwise SUV% contrast ratio (SUV%-CR, calculated as median GTV<sup>majority</sup> SUV% / median prostate gland without GTV<sup>majority</sup> SUV%) was calculated according to the tracer used. A significant difference in overlap% favoring PSMA PET compared with bpMRI was found in the <sup>18</sup>F subgroup (median, 63.0% vs 53.1%; P = .004) but was not present in the <sup>68</sup>Ga subgroup (32.5% vs 50.6%; P = .100). Regarding interobserver variability, measured Sørensen-Dice coefficients (0.58 vs 0.72) and calculated mean distances to agreement (2.44 mm vs 1.22 mm) were statistically significantly lower and higher, respectively, for the <sup>18</sup>F cohort compared with the <sup>68</sup>Ga cohort. For the bpMRI-based delineations, the median Sørensen-Dice coefficient and mean distance to agreement were 0.63 and 1.76 mm, respectively. Median patientwise SUV%-CRs of 1.8 (interquartile range [IQR], 1.6-2.7) for <sup>18</sup>F-PSMA and 3.3 (IQR, 2.7-5.9) for <sup>68</sup>Ga-PSMA PET images were found. Both MRI and PSMA PET provided consistent intraprostatic GTV lesion detection. However, the PSMA tracer seems to have a major influence on the contour characteristics, owing to an apparent difference in SUV% distribution in the prostate gland.

Medical subject headings