Repeatability and Biofidelity of a Physical Surrogate Neck Model Fit to a Hybrid III Head.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 33999296.
- Also identified by DOI 10.1007/s10439-021-02786-z.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In helmet impact testing, parameters including acceleration and velocity are measured using instrumented head-neck models that are meant to be mechanically realistic (i.e. biofidelic) stand-ins, or surrogates, for humans. Currently available models of the human neck are designed primarily for application in automotive crash testing, and their applicability in assessment of helmets is often questioned. The object of the present work is to document the mechanical design, repeatability, and biofidelity in low speed impact of a new neck model that we apply with a Hybrid III head. Focusing on Hybrid III head kinematics measured during impacts at 2 to 6 m/s, the co-efficient of variance of repeated measures of kinematics was generally less than 10%. Differences in kinematics between identical copies of the neck was less than 20% when tested with helmets, and less than 7% when the head was not helmeted. In parallel testing using a Hybrid III head-neck, the co-efficient of variance in repeated measures was less than 4% and the kinematics significantly differed from those measured using the new neck. CORAplus scores for the new neck were approximately 0.70 when compared against data for human subjects with passive neck muscles experiencing impact at 2 m/s.
Medical subject headings
- Head
- Models, Anatomic
- Models, Biological
- Neck
- Neck Muscles