MODIFIED SUTURELESS INTRASCLERAL FIXATION TECHNIQUE FOR SECONDARY INTRAOCULAR LENS IMPLANTATION: A Pilot Study.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 34050099.
- Also identified by DOI 10.1097/IAE.0000000000003220.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To demonstrate possible complications of a new intraocular lens for sutureless secondary scleral implantation and modifications of the surgical technique to optimize outcomes. A retrospective study of 16 eyes (16 patients) who underwent a secondary intraocular lens implantation using the Carlevale intraocular lens (Soleko, Italy) with two anchor haptics for intrascleral implantation (mean follow-up 2.2 months). The visual acuity did not improve statistically significantly postoperatively ( P = 0.601). Seven (44%) patients suffered from postoperative hypotonia (intraocular pressure <5 mmHg) during the first three postoperative days. Owing to the early postoperative hypotony, we decided to modify the surgical technique. We present several suggestions to optimize the technique and outcome such as positioning the sclerotomies at the 2 and 8 o'clock positions, using 27 G trocars alone and suturing the frown incisions using self-resorbing sutures.
Medical subject headings
- Lens Implantation, Intraocular
- Lenses, Intraocular