Performance of a novel temporary arterial shunt in a military-relevant controlled hemorrhage swine model.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 34117170.
- Also identified by DOI 10.1097/TA.0000000000003282.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In military trauma, temporary vascular shunts restore arterial continuity until delayed vascular reconstruction, often for a period of hours. A novel US Air Force-developed trauma-specific vascular injury shunt (TS-VIS) incorporates an accessible side port for intervention or monitoring, which may improve patency under adverse hemodynamic conditions. Our objective was to evaluate TS-VIS patency in the setting of volume-limited resuscitation from hemorrhagic shock. Female swine (70-90 kg) underwent 30% hemorrhage and occlusion of the left external iliac artery for 30 minutes. Animals were allocated to one of three groups (n = 5 per group) by left external iliac artery treatment: Sundt shunt (SUNDT), TS-VIS with arterial pressure monitoring (TS-VIS), or TS-VIS with heparin infusion (10 μ/kg per hour, TS-VISHep). Animals were resuscitated with up to 3 U of whole blood to maintain a mean arterial pressure (MAP) of >60 mm Hg and were monitored for 6 hours. Bilateral femoral arterial flow was continuously monitored with transonic flow probes, and shunt thrombosis was defined as the absence of flow for greater than 5 minutes. No intergroup differences in MAP or flow were observed at baseline or following hemorrhage. Animals were hypotensive at shunt placement (MAP, 35.5 ± 7.3 mm Hg); resuscitation raised MAP to >60 mm Hg by 26.5 ± 15.5 minutes. Shunt placement required 4.5 ± 1.8 minutes with no difference between groups. Four SUNDT thrombosed (three before 60 minutes). One SUNDT thrombosed at 240 minutes, and two TS-VIS and one TS-VISHep thrombosed between 230 and 282 minutes. Median patency was 21 minutes for SUNDT and 360 minutes for both TS-VIS groups (p = 0.04). While patent, all shunts maintained flow between 60% and 90% of contralateral. The TS-VIS demonstrated sustained patency superior to the Sundt under adverse hemodynamic conditions. No benefit was observed by the addition of localized heparin therapy over arterial pressure monitoring by the TS-VIS side port.
Medical subject headings
- Arteriovenous Shunt, Surgical
- Vascular System Injuries
- War-Related Injuries