Mixed Effect Modeling of Dose and Linear Energy Transfer Correlations With Brain Image Changes After Intensity Modulated Proton Therapy for Skull Base Head and Neck Cancer.
Where this comes from
- Record sourced from PubMed, PMID 34153379.
- Also identified by DOI 10.1016/j.ijrobp.2021.06.016 and PMC identifier 8855940.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
Intensity modulated proton therapy (IMPT) could yield high linear energy transfer (LET) in critical structures and increased biological effect. For head and neck cancers at the skull base this could potentially result in radiation-associated brain image change (RAIC). The purpose of the current study was to investigate voxel-wise dose and LET correlations with RAIC after IMPT. For 15 patients with RAIC after IMPT, contrast enhancement observed on T1-weighted magnetic resonance imaging was contoured and coregistered to the planning computed tomography. Monte Carlo calculated dose and dose-averaged LET (LET<sub>d</sub>) distributions were extracted at voxel level and associations with RAIC were modelled using uni- and multivariate mixed effect logistic regression. Model performance was evaluated using the area under the receiver operating characteristic curve and precision-recall curve. An overall statistically significant RAIC association with dose and LET<sub>d</sub> was found in both the uni- and multivariate analysis. Patient heterogeneity was considerable, with standard deviation of the random effects of 1.81 (1.30-2.72) for dose and 2.68 (1.93-4.93) for LET<sub>d</sub>, respectively. Area under the receiver operating characteristic curve was 0.93 and 0.95 for the univariate dose-response model and multivariate model, respectively. Analysis of the LET<sub>d</sub> effect demonstrated increased risk of RAIC with increasing LET<sub>d</sub> for the majority of patients. Estimated probability of RAIC with LET<sub>d</sub> = 1 keV/µm was 4% (95% confidence interval, 0%, 0.44%) and 29% (95% confidence interval, 0.01%, 0.92%) for 60 and 70 Gy, respectively. The TD<sub>15</sub> were estimated to be 63.6 and 50.1 Gy with LET<sub>d</sub> equal to 2 and 5 keV/µm, respectively. Our results suggest that the LET<sub>d</sub> effect could be of clinical significance for some patients; LET<sub>d</sub> assessment in clinical treatment plans should therefore be taken into consideration.
Medical subject headings
- Head and Neck Neoplasms
- Proton Therapy