Higher CPAP levels improve functional residual capacity at birth in preterm rabbits.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 34294868.
- Also identified by DOI 10.1038/s41390-021-01647-8.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Preterm infants are commonly supported with 4-8 cm H<sub>2</sub>O continuous positive airway pressures (CPAP), although higher CPAP levels may improve functional residual capacity (FRC). Preterm rabbits delivered at 29/32 days (~26-28 weeks human) gestation received 0, 5, 8, 12, 15 cm H<sub>2</sub>O of CPAP or variable CPAP of 15 to 5 or 15 to 8 cm H<sub>2</sub>O (decreasing ~2 cm H<sub>2</sub>O/min) for up to 10 min after birth. FRC was lower in the 0 (6.8 (1.0-11.2) mL/kg) and 5 (10.1 (1.1-16.8) mL/kg) compared to the 15 (18.8 (10.9-22.4) mL/kg) cm H<sub>2</sub>O groups (p = 0.003). Fewer kittens achieved FRC > 15 mL/kg in the 0 (20%), compared to 8 (36%), 12 (60%) and 15 (73%) cm H<sub>2</sub>O groups (p = 0.008). While breathing rates were not different (p = 0.096), apnoea tended to occur more often with CPAP < 8 cm H<sub>2</sub>O (p = 0.185). CPAP belly and lung bulging rates were similar whereas pneumothoraces were rare. Lowering CPAP from 15 to 5, but not 15 to 8 cm H<sub>2</sub>O, decreased FRC and breathing rates. In all, 15 cm H<sub>2</sub>O of CPAP improved lung aeration and reduced apnoea, but did not increase the risk of lung over-expansion, pneumothorax or CPAP belly immediately after birth. FRC and breathing rates were maintained when CPAP was decreased to 8 cm H<sub>2</sub>O. Although preterm infants are commonly supported with 4-8 cm H<sub>2</sub>O CPAP at birth, preclinical studies have shown that higher PEEP levels improve lung aeration. In this study, CPAP levels of 15 cm H<sub>2</sub>O improved lung aeration and reduced apnoea in preterm rabbit kittens immediately after birth. In all, 15 cm H<sub>2</sub>O CPAP did not increase the risk of lung over-expansion (indicated by bulging between the ribs), pneumothorax, or CPAP belly. These results can be used when designing future studies on CPAP strategies for preterm infants in the delivery room.
Medical subject headings
- Apnea
- Pneumothorax