Comparison of [<sup>68</sup> Ga]Ga-FAPI-04 and [<sup>18</sup>F]-FDG for the detection of primary and metastatic lesions in patients with gastric cancer: a bicentric retrospective study.

Jiang, Donglang; Chen, Xing; You, Zhiwen; Wang, Hao; Zhang, Xiaoyun; Li, Xiuming; Ren, Shuhua; Huang, Qi et al. · Eur J Nucl Med Mol Imaging · 2022

retrospective_cohort · Level III

Where this comes from

Abstract

The low sensitivity of [<sup>18</sup>F]-fluorodeoxyglucose ([<sup>18</sup>F]-FDG) for the diagnosis of gastric cancer limits its application. In this study, we aimed to investigate the potential advantage of [<sup>68</sup> Ga]Ga-FAPI-04 over [<sup>18</sup>F]-FDG in the evaluation of gastric cancer. This was a bicentric retrospective analysis of a prospective parent study (clinical trial: HS-KY-2020-826 (Huashan Hospital) and DF-2020-102 (Shanghai East Hospital)). Thirty-eight patients with gastric cancer (31 with adenocarcinoma and 7 with signet ring cell carcinoma) were included in this study. All of the participants underwent [<sup>68</sup> Ga]Ga-FAPI-04 and [<sup>18</sup>F]-FDG imaging by positron emission tomography (PET)/computed tomography (CT) or PET/magnetic resonance (MR). The scans were interpreted by two experienced nuclear medicine physicians, and the maximum standardized uptake value (SUV<sub>max</sub>) was calculated. Histopathological findings obtained from biopsy or resected surgical specimens were used as a reference for the final diagnosis. For the detection of primary gastric cancer, the sensitivities of [<sup>68</sup> Ga]Ga-FAPI-04 PET and [<sup>18</sup>F]-FDG PET were 100% (38/38) and 82% (31/38), respectively (P = 0.016). Four cases of adenocarcinoma and three cases of signet ring cell carcinoma were missed by [<sup>18</sup>F]-FDG PET. The mean SUV<sub>max</sub> of [<sup>68</sup> Ga]Ga-FAPI-04 in tumours greater than 4 cm (11.0 ± 4.5) was higher than that in tumours less than 4 cm (4.5 ± 3.2) (P = 0.0015). The mean SUV<sub>max</sub> of [<sup>68</sup> Ga]Ga-FAPI-04 was higher in T2-4 tumours (9.7 ± 4.4) than in T1 tumours (3.1 ± 1.5) (P = 0.0002). For the detection of metastatic lesions, the sensitivities of [<sup>68</sup> Ga]Ga-FAPI-04 PET and [<sup>18</sup>F]-FDG PET in 10 patients with regional lymph node metastasis and distant metastasis were 6/10 and 5/10, respectively. In this selected cohort, [<sup>68</sup> Ga]Ga-FAPI-04 PET had a superior detection rate than [<sup>18</sup>F]-FDG PET for primary gastric cancer. [<sup>68</sup> Ga]Ga-FAPI-04 PET could provide better performance with regard to gastric cancer diagnosis and staging. Prospective clinical trials are warranted.

Medical subject headings