Biodegradable Stent Placement for Airway Kinking After Bronchoscopic Lung Volume Reduction Treatment.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 34314690.
- Also identified by DOI 10.1016/j.athoracsur.2021.07.011.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Symptomatic airway kinking after bronchoscopic lung volume reduction with endobronchial valves is rare. Owing to the development of the desired lobar atelectasis, the position of the airways of the nontreated lobe changes, and that might lead to invalidating symptoms. We present a case of a patient with symptomatic airway kinking after treatment with endobronchial valves, who was successfully treated with a single placement of a biodegradable stent. Placement of a biodegradable stent can be considered for symptomatic patients with airway kinking.
Medical subject headings
- Pneumonectomy
- Pulmonary Atelectasis