All-Inside Repair for Radial Tear at the Posterior Horn of the Lateral Meniscus: A Figure-8 Suture Technique.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 34401242.
- Also identified by DOI 10.1016/j.eats.2021.04.021 and PMC identifier 8355411.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Arthroscopic suture repair for a radial tear at the posterior horn of the lateral meniscus poses a technical procedure for surgeons. We describe an all-inside repair technique using all-inside meniscal repair devices without adding any accessory portals. This simple technique provides precise reduction and stabilization of the meniscus by pinching 2 all-inside vertical sutures consecutively across the tear site.