Single sterile silicon ring technique for utilization of upper limb intravenous regional anesthesia: A prospective study of patients with operated distal radius fractures.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 34420690.
- Also identified by DOI 10.1016/j.injury.2021.08.011.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Intravenous regional anesthesia is a well-established method of anesthesia in upper extremity surgery. In this study, we present a modification of the technique using a silicon ring tourniquet in 30 patients undergoing internal fixation for distal radius fractures. A sterile silicone ring wrapped within a stockinette sleeve was applied, and a local anesthetic solution (3 mg/kg lidocaine 0,5%) was injected intravenously. After anesthesia onset, the ring was rolled distally to provide immediate pain and discomfort relief. The silicone ring achieved adequate exsanguination in all patients. Mean pain VAS score was 2.7 ± 0.9 intraoperatively and 4.3 ± 1.3 during the first hour postoperatively. The onset and termination times of sensory block were 5.8 ± 2.1 and 102 ± 7.8 min, and of motor block 13.8 ± 2.8 and 54.2 ± 4.6 min, accordingly. All patients were satisfied from the procedure. Sterile silicone ring tourniquet application is a simple, safe and effective analgesic and anesthetic technique for the operative treatment of distal radius fractures.
Medical subject headings
- Anesthesia, Conduction
- Radius Fractures