Cubitus Varus Corrective Osteotomy and Graft Fashioning Using Computer Simulated Bone Reconstruction and 3D Printed Custom-Made Cutting Guides.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 34423098.
- Also identified by DOI 10.22038/abjs.2020.52457.2592 and PMC identifier 8359662.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Preoperative planning is of paramount importance in saving time as well as helping achieve a more precise correction of the deformities. Along with preoperative measurements, customized cutting guides can facilitate intraoperative correction of the deformity with higher confidence. In this report, we are presenting the application of preoperative planning and 3D printed customized cutting guides for correcting cubitus varus alignment of the elbow in an 18 year old male with satisfactory intraoperative and postoperative results.