Ten-Year Survivorship and Risk of Periprosthetic Fracture of a Cementless Tapered Stem.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 34538344.
- Also identified by DOI 10.1016/j.ocl.2021.05.005.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This article is a retrospective review of a consecutive series of 401 primary total hip arthroplasties with the use of cementless, ream and broach Synergy stem (Smith & Nephew, Memphis, TN, USA) with minimal 10-year follow-up. We report an overall 10-year survivorship of 99.6% with a total of 15 fractures during the study period. Six of these fractures occurred intraoperatively. This is the largest series to our knowledge reporting greater than 10-year follow-up. This stem has excellent survivorship with overall low risk of periprosthetic fracture.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
- Periprosthetic Fractures
- Prosthesis Design
Anatomy
- hip