Defining growth in small pulmonary nodules using volumetry: results from a "coffee-break" CT study and implications for current nodule management guidelines.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 34580748.
- Also identified by DOI 10.1007/s00330-021-08302-0 and PMC identifier 8831344.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
An increase in lung nodule volume on serial CT may represent true growth or measurement variation. In nodule guidelines, a 25% increase in nodule volume is frequently used to determine that growth has occurred; this is based on previous same-day, test-retest (coffee-break) studies examining metastatic nodules. Whether results from prior studies apply to small non-metastatic nodules is unknown. This study aimed to establish the interscan variability in the volumetric measurements of small-sized non-metastatic nodules. Institutional review board approval was obtained for this study. Between March 2019 and January 2021, 45 adults (25 males; mean age 65 years, range 37-84 years) with previously identified pulmonary nodules (30-150 mm<sup>3</sup>) requiring surveillance, without a known primary tumour, underwent two same-day CT scans. Non-calcified solid nodules were measured using commercial volumetry software, and interscan variability of volume measurements was assessed using a Bland-Altman method and limits of agreement. One hundred nodules (range 28-170 mm<sup>3</sup>; mean 81.1 mm<sup>3</sup>) were analysed. The lower and upper limits of agreement for the absolute volume difference between the two scans were - 14.2 mm<sup>3</sup> and 12.0 mm<sup>3</sup> respectively (mean difference 1.09 mm<sup>3</sup>, range - 33-12 mm<sup>3</sup>). The lower and upper limits of agreement for relative volume difference were - 16.4% and 14.6% respectively (mean difference 0.90%, range - 24.1-32.8%). The interscan volume variability in this cohort of small non-metastatic nodules was smaller than that in previous studies involving lung metastases of varying sizes. An increase of 15% in nodule volume on sequential CT may represent true growth, and closer surveillance of these nodules may be warranted. • In current pulmonary nodule management guidelines, a threshold of 25% increase in volume is required to determine that true growth of a pulmonary nodule has occurred. • This test-retest (coffee break) study has demonstrated that a smaller threshold of 15% increase in volume may represent true growth in small non-metastatic nodules. • Closer surveillance of some small nodules growing 15-25% over a short interval may be appropriate.
Medical subject headings
- Lung Neoplasms
- Multiple Pulmonary Nodules
- Solitary Pulmonary Nodule