Similar infection rates in a new wound closure method following knee arthroplasty.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 34616118.
- Also identified by DOI 10.1016/j.jor.2021.09.009 and PMC identifier 8476446.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Surgical site infections, defined as acute wound infections requiring surgical intervention within 90 days post-surgery, were retrospectively compared between a novel, zipper-like closure method (ZM) and staples in 682 patients (904 knees) and 772 patients (971 knees), respectively. The incidence of deep infections was 0.6% for staples and 0.2% for ZM (p = 0.169) and superficial infections was 0.1% for staples and 0.0% for ZM (p = 0.518). With no difference in wound complications, the ZM may be preferred since the two-week post-operative clinic visit required for wound check and staple removal was eliminated, thereby, decreasing clinic volume.