Long-term results of treatment of infrarenal aortic aneurysms with low-profile stent grafts in a multicenter registry.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 34634415.
- Also identified by DOI 10.1016/j.jvs.2021.09.036.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In recent years, manufacturers have developed new stent grafts with lower profiles to increase the endovascular aneurysm repair applicability. As reported by the current European Society for Vascular Surgery guidelines, long-term evaluation of such low-profile platforms is strongly recommended. This study aims to report outcomes beyond 5 years from a multicenter registry, including a real-world cohort of patients electively treated with low-profile stent grafts. A retrospective data collection of patients who had undergone elective implantation of low-profile endograft ≤16 Fr. (Zenith LP, Ovation, Incraft) was performed in nine centers. The primary endpoint was a long-term primary clinical success. Secondary endpoints were survival rate, freedom from abdominal aortic aneurysm (AAA)-related death, freedom from type I to III endoleak, limb patency, and freedom from all reinterventions. The Kaplan-Meier curves were stratified for investigative devices. A multivariate analysis evaluated predictors of primary clinical success and reintervention rate. A total of 619 patients were enrolled (Ovation, n = 373; Incraft, n = 111; and Zenith LP, n = 135), with a mean follow-up of 56.8 ± 22.8 months. The overall primary and the secondary clinical success rate at 8 years was 72.1% and 93.8%, respectively. At 8 years, overall survival was 53.2%, freedom from AAA-related death was 94.4%, freedom from reintervention was 74%, freedom from type I/III endoleak was 86.9%, and limb patency was 90.4%. A significantly worse primary clinical success of the Zenith LP was recorded as dependent on more limb-related events. No differences between platforms were registered in the rate of AAA-related deaths, open conversion, sac enlargement, and type I/III endoleaks (P = .26). Multivariate analysis identified iliac tortuosity (hazard ratio, 2.053) and Zenith LP (hazard ratio, 3.818) as significant independent predictors of clinical failure and reintervention. Low-profile stent grafts have acceptable long-term outcomes. Overall survival and AAA-related death were in line with those reported for traditional devices. Long-term surveillance and reintervention, when necessary, remain crucial to guarantee durability.
Medical subject headings
- Aortic Aneurysm, Abdominal
- Blood Vessel Prosthesis Implantation
- Endovascular Procedures