Medium-term rates of radiolucency after primary total shoulder arthroplasty using a cementless metal-backed pegged polyethylene glenoid.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 34659468.
- Also identified by DOI 10.1177/1758573219901122 and PMC identifier 8512994.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Total shoulder arthroplasty is an established treatment with the commonest cause of failure loosening of the glenoid component. Hydroxyapatite metal-backed glenoid components could offer better survivorship due to improved fixation. The aim of this study was to investigate periprosthetic radiolucency rates associated with an uncemented, metal-backed polyethylene glenoid component with medium-term results. A single centre retrospective study examining radiological outcomes of the Epoca metal-backed glenoid component. Radiographs were analysed for post-operative adequacy of glenoid seating and radiographs at follow-up assessed for periprosthetic lucencies and any revision procedures were recorded. Forty-one patients were followed up with a mean follow-up time of 5.5 years (3-8 years). Primary indication for total shoulder arthroplasty was osteoarthritis (80%). Mean age was 69 years (53-86 years). Ninety-five per cent of glenoid components were completely seated. At follow-up six patients had undergone revision (14.6%). Thirty of the remaining patients (86%) did not demonstrate any radiolucency on follow-up radiographs. Complete glenoid seating post-operatively was associated with lower rate of subsequent radiolucency and revision (P < 0.01). Low rates of radiolucency at medium-term follow-up with an uncemented metal-backed glenoid, however significant rates of revision. Complete seating of the glenoid component was associated with lower rates of radiolucency and revision.
Anatomy
- shoulder