Clinical and radiological results of high offset tri-lock bone preservation stem in unilateral primary total hip arthroplasty at a minimum follow-up of 3 years.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 34689823.
- Also identified by DOI 10.1186/s13018-021-02787-7 and PMC identifier 8543806.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
Although the high offset Tri-Lock bone preservation stem (BPS) was used widely, few studies explored the clinical and radiological results. The purpose of this study was to determine the clinical and radiological results of high offset Tri-Lock BPS in unilateral primary total hip arthroplasty (THA) at a minimum follow-up of 3 years. 55 patients who underwent cementless THA with high offset Tri-lock BPS from 2017 to 2018 were followed for a minimum follow-up of 3 years. Patients were assessed clinically for complications, Harris hip score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Oxford Hip Score (OHS). Femoral offset (FO), acetabular offset (AO), hip offset (HO), HO difference, and leg length discrepancy (LLD) were measured on the anteroposterior (AP) pelvic radiograph. Standard pelvic AP and lateral radiographs were used to evaluate for evidence of bone ingrowth, stem subsidence, stem alignment, radiolucent line around the stem, osteolysis, loosening, ectopic ossification, and femoral stress shielding. No patients reported complications during hospitalization nor the follow-up period. At a mean follow-up of 42.5 months, the mean HHS, WOMAC, and OHS scores showed a significant improvement from preoperative to the latest follow-up. No patients reported thigh pain. No revision nor sign of radiographic loosening had been detected. The high offset Tri-Lock BPS significantly improved the FO and HO postoperatively. HO difference and LLD were balanced postoperatively. No sign of stem subsidence, radiolucent line, osteolysis, loosening, ectopic ossification, nor severe stress shielding (more than grade 3-4) were observed at the latest follow-up. The high offset Tri-Lock BPS demonstrated excellent clinical and radiographic outcomes at a minimum follow-up of 3 years. HO difference and LLD between legs decreased significantly and achieved balance postoperatively. Long-term follow-up is required for a definitive conclusion.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
- Ossification, Heterotopic
- Osteolysis
Anatomy
- hip