Clinical and Dosimetric Implications of Calculating Lung Shunt Fraction for Hepatic <sup>90</sup>Y Radioembolization Using SPECT/CT Versus Planar Scintigraphy.

Struycken, Lucas; Patel, Mikin; Kuo, Phillip; Hennemeyer, Charles; Woodhead, Gregory; McGregor, Hugh · AJR Am J Roentgenol · 2022

retrospective_cohort · Level III

Where this comes from

Abstract

<b>BACKGROUND.</b> Accurate assessment of hepatopulmonary shunting, typically performed by planar scintigraphy, is critical in planning <sup>90</sup>Y radioembolization. High lung shunt fractions (LSFs) may alter treatment. <b>OBJECTIVE.</b> The purpose of this study is to compare LSFs calculated from planar scintigraphy versus SPECT/CT in patients with high planar LSFs (> 15%) and to describe the potential clinical and dosimetric implications of SPECT/CT LSF calculations. <b>METHODS.</b> This retrospective study included 36 patients (29 men and seven women; mean age, 62.4 ± 9.8 [SD] years) who underwent <sup>99m</sup>Tc-macroaggregated albumin (MAA) planar scintigraphy for planning hepatic radioembolization, had a planar LSF greater than 15%, and underwent concurrent SPECT/CT. Clinically reported planar LSFs were recorded. SPECT/CT LSFs were retrospectively calculated using automatically generated volumetric ROIs around the lungs and liver with subsequent manual adjustments. Total lung and perfused liver doses were calculated using a medical internal radiation dose model. Values derived from planar and SPECT/CT data were compared using Mann-Whitney <i>U</i> tests. Multivariable regression analysis was performed of factors associated with the discrepancy in LSF between the techniques. <b>RESULTS.</b> Mean planar LSF was 25.1% ± 11.6%, and mean SPECT/CT LSF was 16.0% ± 9.3% (<i>p</i> < .001). Mean lung dose was 18.8 ± 8.0 Gy for planar LSF versus 12.3 ± 7.2 Gy for SPECT/CT LSF (<i>p</i> < .001). Mean perfused liver dose was 92.9 ± 36.1 Gy using planar LSF versus 102.7 ± 39.1 Gy using SPECT/CT LSF (<i>p</i> < .001). In multivariable analysis, a larger discrepancy in LSF between planar scintigraphy and SPECT/CT was associated with a body mass index (weight in kilograms divided by the square of height in meters) of 26 or higher (<i>p</i> = .02), maximum tumor size of less than 9 cm (<i>p</i> = .05), and left hepatic intraarterial injection (<i>p</i> = .02). Fourteen of 36 patients did not undergo upfront radioembolization due to a planar LSF greater than 20% and instead underwent shunt-reducing embolization with subsequent radioembolization (<i>n</i> = 7), transarterial chemoembolization (<i>n</i> = 5), or no treatment (<i>n</i> = 2). Five of these 14 patients had a SPECT/CT LSF of less than 20% and would have been eligible for upfront radioembolization based on SPECT/CT LSF. Seven of 29 patients treated with radioembolization underwent prescribed dose reductions based on planar LSF; six of these patients would have qualified for standard radioembolization without dose reduction using SPECT/CT LSF. <b>CONCLUSION.</b> Planar scintigraphy yields greater LSFs compared with SPECT/CT, possibly leading to unnecessary shunt-reducing procedures and prescribed dose reductions. <b>CLINICAL IMPACT.</b> SPECT/CT should be considered for clinical LSF calculations before radioembolization in patients with high LSFs.

Medical subject headings