Lung Dose Measured on Postradioembolization <sup>90</sup>Y PET/CT and Incidence of Radiation Pneumonitis.
Where this comes from
- Record sourced from PubMed, PMID 34772794.
- Also identified by DOI 10.2967/jnumed.121.263143 and PMC identifier 9258566.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Radiation pneumonitis is a rare but possibly fatal side effect of <sup>90</sup>Y radioembolization. It may occur 1-6 mo after therapy, if a significant part of the <sup>90</sup>Y microspheres shunts to the lungs. In current clinical practice, a predicted lung dose greater than 30 Gy is considered a criterion to exclude patients from treatment. However, contrasting findings regarding the occurrence of radiation pneumonitis and lung dose were previously reported in the literature. In this study, the relationship between the lung dose and the eventual occurrence of radiation pneumonitis after <sup>90</sup>Y radioembolization was investigated. <b>Methods:</b> We retrospectively analyzed 317 <sup>90</sup>Y liver radioembolization procedures performed during an 8-y period (February 2012 to September 2020). We calculated the predicted lung mean dose (LMD) using <sup>99m</sup>Tc-MAA planar scintigraphy (LMD<sub>MAA</sub>) acquired during the planning phase and left LMD (LMD<sub>Y-90</sub>) using the <sup>90</sup>Y PET/CT acquired after the treatment. For the lung dose computation, we used the left lung as the representative lung volume, to compensate for scatter from the liver moving in the craniocaudal direction because of breathing and mainly affecting the right lung. <b>Results:</b> In total, 272 patients underwent <sup>90</sup>Y procedures, of which 63% were performed with glass microspheres and 37% with resin microspheres. The median injected activity was 1,974 MBq (range, 242-9,538 MBq). The median LMD<sub>MAA</sub> was 3.5 Gy (range, 0.2-89.0 Gy). For 14 procedures, LMD<sub>MAA</sub> was more than 30 Gy. Median LMD<sub>Y-90</sub> was 1 Gy (range, 0.0-22.1 Gy). No patients had an LMD<sub>Y-90</sub> of more than 30 Gy. Of the 3 patients with an LMD<sub>Y-90</sub> of more than 12 Gy, 2 patients (one with an LMD<sub>Y-90</sub> of 22.1 Gy and an LMD<sub>MAA</sub> of 89 Gy; the other with an LMD<sub>Y-90</sub> of 17.7 Gy and an LMD<sub>MAA</sub> of 34.1 Gy) developed radiation pneumonitis and consequently died. The third patient, with an LMD<sub>Y-90</sub> of 18.4 Gy (LMD<sub>MAA</sub>, 29.1 Gy), died 2 mo after treatment, before the imaging evaluation, because of progressive disease. <b>Conclusion:</b> The occurrence of radiation pneumonitis as a consequence of a lung shunt after <sup>90</sup>Y radioembolization is rare (<1%). No radiation pneumonitis developed in patients with a measured LMD<sub>Y-90</sub> lower than 12 Gy.
Medical subject headings
- Embolization, Therapeutic
- Liver Neoplasms
- Pneumonia
- Radiation Pneumonitis