The Alarm Burden of Excess Continuous Pulse Oximetry Monitoring Among Patients With Bronchiolitis.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 34798003.
- Also identified by DOI 10.12788/jhm.3731 and PMC identifier 8626057.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Guidelines discourage continuous pulse oximetry monitoring of hospitalized infants with bronchiolitis who are not receiving supplemental oxygen. Excess monitoring is theorized to contribute to increased alarm burden, but this burden has not been quantified. We evaluated admissions of 201 children (aged 0-24 months) with bronchiolitis. We categorized time ≥60 minutes following discontinuation of supplemental oxygen as "continuously monitored (guideline-discordant)," "intermittently measured (guideline-concordant)," or "unable to classify." Across 4402 classifiable hours, 77% (11,101) of alarms occurred during periods of guideline-discordant monitoring. Patients experienced a median of 35 alarms (interquartile range [IQR], 10-81) during guideline-discordant, continuously monitored time, representing a rate of 6.7 alarms per hour (IQR, 2.1-12.3). In comparison, the median hourly alarm rate during periods of guideline-concordant intermittent measurement was 0.5 alarms per hour (IQR, 0.1-0.8). Reducing guideline-discordant monitoring in bronchiolitis patients would reduce nurse alarm burden.