Diagnostic Performance of Cervical Ultrasound, <sup>99m</sup>Tc-Sestamibi Scintigraphy, and Contrast-Enhanced <sup>18</sup>F-Fluorocholine PET in Primary Hyperparathyroidism.
Where this comes from
- Record sourced from PubMed, PMID 34857659.
- Also identified by DOI 10.2967/jnumed.121.261900.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Preoperative localization of pathologic parathyroids is crucial for minimally invasive treatment of primary hyperparathyroidism (PHPT). This study compared contrast-enhanced <sup>18</sup>F-fluorocholine PET/CT, cervical ultrasonography (CU), and conventional scintigraphic imaging modalities (MIBI scintigraphy, consisting of <sup>99m</sup>Tc-sestamibi/<sup>123</sup>I-sodium iodide SPECT/CT, <sup>99m</sup>Tc-sestamibi/<sup>123</sup>I-sodium iodide planar subtraction imaging, and <sup>99m</sup>Tc-sestamibi planar dual-phase imaging), combined and individually, for preoperative localization of hyperfunctional parathyroids in PHPT. The gold standard was histologic examination. <b>Methods:</b> Data from consecutive patients with clinically suspected PHPT were retrospectively collected. All 3 imaging modalities were systematically performed. The ability of <sup>18</sup>F-fluorocholine PET/CT, CU, and MIBI scintigraphy to identify a hyperfunctional parathyroid and specify the side or identify an ectopic location was noted. Patients underwent surgical exploration if at least 1 examination was positive. The findings of CU + MIBI scintigraphy combined were considered positive if CU and MIBI scintigraphy separately showed a hyperfunctional parathyroid gland on the same side or in the same ectopic location; any findings other than these were considered negative. The composite judgment criterion for pathologic parathyroid was a combination of histologic analysis and normalization of parathyroid hormone and calcium levels. <b>Results:</b> In total, 149 pathologic parathyroids were found in 143 of the 144 included patients. <sup>18</sup>F-fluorocholine PET/CT diagnosed 148 of 149 pathologic parathyroids. Only 4 false-positives and 1 false-negative were found. The <sup>18</sup>F-fluorocholine PET/CT sensitivity of 99.3% was superior to that of CU, at 75.2% (<i>P</i> < 0.0001); MIBI scintigraphy, at 65.1% (<i>P</i> < 0.0001); and CU + MIBI scintigraphy, at 89.9%, (<i>P</i> = 0.0009). Five of the 5 ectopic locations were diagnosed by <sup>18</sup>F-fluorocholine PET/CT, 2 of the 5 by MIBI scintigraphy, and none by CU. Accuracy was better for <sup>18</sup>F-fluorocholine PET/CT, at 98%, than for CU, at 84% (<i>P</i> < 0.0001); MIBI scintigraphy, at 81% (<i>P</i> < 0.0001); or CU + MIBI scintigraphy, at 91% (<i>P</i> < 0.0001). Among the 72 (50%) patients who had a negative CU + MIBI scintigraphy result, <sup>18</sup>F-fluorocholine PET/CT correctly identified hyperfunctional thyroids in 70 (97.2%). Average uptake in the <sup>18</sup>F-fluorocholine PET/CT hyperfunctional parathyroid was higher than that in the adjacent thyroid (SUV<sub>max</sub> adjusted for lean body mass, 6.45 vs. 2.15) (<i>P</i> < 0.0001). <b>Conclusion:</b> The accuracy of <sup>18</sup>F-fluorocholine PET/CT is higher than that of CU and MIBI scintigraphy for localization of hyperfunctional parathyroids, justifying the systematic use of <sup>18</sup>F-fluorocholine PET/CT as the first-line method for PHPT diagnosis.
Medical subject headings
- Hyperparathyroidism, Primary