Radiation Protection and Occupational Exposure on <sup>68</sup>Ga-PSMA-11-Based Cerenkov Luminescence Imaging Procedures in Robot-Assisted Prostatectomy.

Costa, Pedro Fragoso; Fendler, Wolfgang P; Herrmann, Ken; Sandach, Patrick; Grafe, Hong; Grootendorst, Maarten R; Püllen, Lukas; Kesch, Claudia et al. · J Nucl Med · 2022

Where this comes from

Abstract

Cerenkov luminescence imaging (CLI) was successfully implemented in the intraoperative context as a form of radioguided cancer surgery, showing promise in the detection of surgical margins during robot-assisted radical prostatectomy. The present study was designed to provide a quantitative description of the occupational radiation exposure of surgery and histopathology personnel from CLI-guided robot-assisted radical prostatectomy after the injection of <sup>68</sup>Ga-PSMA-11 in a single-injection PET/CT CLI protocol. <b>Methods:</b> Ten patients with preoperative <sup>68</sup>Ga-PSMA-11 administration and intraoperative CLI were included. Patient dose rate was measured before PET/CT (<i>n</i> = 10) and after PET/CT (<i>n</i> = 5) at a 1-m distance for 4 patient regions (head [A], right side [B], left side [C], and feet [D]). Electronic personal dosimetry (EPD) was used for intraoperative occupational exposure (<i>n</i> = 10). Measurements included the first surgical assistant and scrub nurse at the operating table and the CLI imager/surgeon at the robotic console and encompassed the whole duration of surgery and CLI image acquisition. An estimation of the exposure of histopathology personnel was performed by measuring prostate specimens (<i>n</i> = 8) with a germanium detector. <b>Results:</b> The measured dose rate value before PET/CT was 5.3 ± 0.9 (average ± SD) μSv/h. This value corresponds to a patient-specific dose rate constant for positions B and C of 0.047 μSv/h⋅MBq. The average dose rate value after PET/CT was 1.04 ± 1.00 μSv/h. The patient-specific dose rate constant values corresponding to regions A to D were 0.011, 0.026, 0.024, and 0.003 μSv/h⋅MBq, respectively. EPD readings revealed average personal equivalent doses of 9.0 ± 7.1, 3.3 ± 3.9, and 0.7 ± 0.7 μSv for the first surgical assistant, scrub nurse, and CLI imager/surgeon, respectively. The median germanium detector-measured activity of the prostate specimen was 2.96 kBq (interquartile range, 2.23-7.65 kBq). <b>Conclusion:</b> Single-injection <sup>68</sup>Ga-PSMA-11 PET/CT CLI procedures are associated with a reasonable occupational exposure level, if kept under 110 procedures per year. Excised prostate specimen radionuclide content was below the exemption level for <sup>68</sup>Ga. Dose rate-based calculations provide a robust estimation for EPD measurements.

Medical subject headings