Sutureless Repair With Extended Atriotomy for Post-Repair Pulmonary Venous Obstruction.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 34922910.
- Also identified by DOI 10.1016/j.athoracsur.2021.11.022.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Post-repair pulmonary venous obstruction is a common cause of reoperation after total anomalous pulmonary venous return repair. Herein, we report 3 cases of specific type of post-repair pulmonary venous obstruction with eccentric stenosis of pulmonary vein ostium due to retained composite neoseptum and the technique used for subsequent repair.
Medical subject headings
- Pulmonary Veins
- Pulmonary Veno-Occlusive Disease
- Scimitar Syndrome
- Sutureless Surgical Procedures