Are short press-fit stems comparable to standard-length cemented stems in reverse shoulder arthroplasty? A prospective, randomized clinical trial.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 34968694.
- Also identified by DOI 10.1016/j.jse.2021.11.005.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The literature comparing humeral implants in reverse shoulder arthroplasty is sparse. With minimal supporting literature, there has been a trend away from standard-length cemented humeral implants to press-fit stems and, recently, to shorter-stem implants. It is known that early implant migration, within the first 2 years postoperatively, is predictive of later implant loosening and possible revision surgery. Therefore, the purpose of this study was to compare clinical outcomes and implant migration between cemented standard-length humeral stems and press-fit short stems using model-based radiostereometric analysis. After a power analysis, 41 shoulders were prospectively randomized to receive either a cemented standard-length or press-fit short humeral stem for primary reverse shoulder arthroplasty between July 2017 and June 2019. Following surgery, participants were imaged with stereo radiographs acquired at 6 weeks (baseline), 3 months, 6 months, 1 year, and 2 years. Migration of the humeral stem at each time point was compared with baseline, with differences in migration between cohorts assessed using a mixed-effects model with the Bonferroni test for multiple comparisons. Patient-reported outcome measures (Subjective Shoulder Value; American Shoulder and Elbow Surgeons shoulder score; Simple Shoulder Test score; Disabilities of the Arm, Shoulder and Hand score; and Constant score) were also compared. At 6 months (P = .025), 1 year (P = .004), and 2 years (P = .001) postoperatively, press-fit short stems migrated significantly more than cemented stems along the superior-inferior translation axis; in addition, they showed greater total translation at 2 years (P = .003). Mean total translation (± standard deviation) at 2 years was 0.4 ± 0.2 mm and 1.0 ± 1.1 mm for the cemented and press-fit cohorts, respectively. Mean migration between the 1- and 2-year time points was minimal for both stem fixation groups along all axes (<0.1 mm and 0.6°). There was no difference in active range of motion, pain, or validated outcome measures between the cohorts at 2 years (P ≥ .170). This randomized clinical trial shows that press-fit short humeral stems subside substantially more than standard-length cemented stems but ultimately achieve stability from 1 year through 2 years. Conversely, no significant differences were observed in clinical outcomes between cohorts.
Medical subject headings
- Arthroplasty, Replacement, Shoulder
- Shoulder Joint
- Shoulder Prosthesis
Anatomy
- shoulder