Development and Validation of a Novel At-home Smell Assessment.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 35024772.
- Also identified by DOI 10.1001/jamaoto.2021.3994 and PMC identifier 8759030.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Current tools for diagnosis of olfactory dysfunction (OD) are costly, time-consuming, and often require clinician administration. To develop and validate a simple screening assessment for OD using common household items. This fully virtual diagnostic study included adults with self-reported OD from any cause throughout the US. Data were collected from December 2020 to April 2021 and analyzed from May 2021 to July 2021. Participants with self-reported olfactory dysfunction took a survey assessing smell perception of 45 household items and completed the Clinical Global Impression-Severity (CGI-S) smell questionnaire, the University of Pennsylvania Smell Identification Test (UPSIT), and the 36-item Short Form Survey (SF-36). Psychometric and clinimetric analyses were used to consolidate 45 household items into 2 short Novel Anosmia Screening at Leisure (NASAL) assessments, NASAL-7 (range, 0-14; lower score indicating greater anosmia) and NASAL-3 (range, 0-6; lower score indicating greater anosmia). A total of 115 participants were included in the study, with a median (range) age of 42 (19-70) years, 92 (80%) women, and 97 (84%) White individuals. There was a moderate correlation between the UPSIT and NASAL-7 scores and NASAL-3 scores (NASAL-7: ρ = 0.484; NASAL-3: ρ = 0.404). Both NASAL-7 and NASAL-3 had moderate accuracy in identifying participants with anosmia as defined by UPSIT (NASAL-7 area under the receiver operating curve [AUC], 0.706; 95% CI, 0.551-0.862; NASAL-3 AUC, 0.658; 95% CI, 0.503-0.814). Scoring 7 or less on the NASAL-7 had 70% (95% CI, 48%-86%) sensitivity and 53% (95% CI, 43%-63%) specificity in discriminating participants with anosmia from participants without. Scoring 2 or less on the NASAL-3 had 57% (95% CI, 36%-76%) sensitivity and 78% (95% CI, 69%-85%) specificity in discriminating participants with anosmia from participants without. There was moderate agreement between UPSIT-defined OD categories and those defined by NASAL-7 (weighted κ = 0.496; 95% CI, 0.343-0.649) and those defined by NASAL-3 (weighted κ = 0.365; 95% CI, 0.187-0.543). The agreement with self-reported severity of olfactory dysfunction as measured by CGI-S and the NASAL-7 and NASAL-3 was moderate, with a weighted κ of 0.590 (95% CI, 0.474-0.707) for the NASAL-7 and 0.597 (95% CI, 0.481-0.712) for the NASAL-3. The findings of this diagnostic study suggest that NASAL-7 and NASAL-3, inexpensive and brief patient-reported assessments, can be used to identify individuals with OD. As the burden of COVID-19-associated OD increases, these assessments may prove beneficial as screening and diagnostic tools. Future work will explore whether the NASAL assessments are sensitive to change and how much of a change is clinically important.
Medical subject headings
- COVID-19
- Olfaction Disorders