Procedure-Specific Relationships Between Postoperative Troponin T and a Composite of Mortality and Low Cardiac Output Syndrome: A Retrospective Cohort Analysis.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 35110515.
- Also identified by DOI 10.1213/ANE.0000000000005850.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Myocardial injury after coronary artery bypass grafting (CABG) is defined as troponin concentrations >10 times 99th percentile upper reference limit (URL) according to the Fourth Universal Definition. However, troponin concentrations after non-CABG cardiac surgery which indicate greater-than-expected myocardial injury and increased risk for complications remain unclear. Our goal was to assess procedure-specific relationships between troponin T and a composite outcome of low cardiac output syndrome and in-hospital mortality in cardiac surgical patients. Patients having cardiac surgery between January 2010 and December 2017 were categorized into 4 groups by procedure: (1) CABG; (2) mitral valve repair; (3) aortic valve repair/replacement (AVR); (4) mitral valve replacement (MVR) or CABG + valve surgeries. Exclusion criteria were elevated preoperative troponin T, preoperative kidney failure, circulatory arrest, or preoperative/planned mechanical circulatory support. Logistic regression was used to assess the association between troponin T and composite outcome, both overall and by procedure, including assessment of the interaction between procedure and troponin T on outcome. Among 10,253 patients, 37 (0.4%) died and 393 (3.8%) developed the primary outcome. Troponin T concentrations differed by procedure (P < .001). Compared to CABG, AVR had 0.53 (99.2% confidence interval [CI], 0.50-0.56; unadjusted P < .001) times lower troponin T concentrations, while MVR/CABG + valve were 1.54 (99.2% CI, 1.45-1.62, unadjusted P < .001) times higher. There were linear relationships between log2 troponin T concentration and log odds mortality/low cardiac output syndrome. The (unadjusted) relationships were parallel for various types of surgery (interaction P = .59), but at different levels of the outcome. The relative increase in odds for mortality/low cardiac output syndrome per a similar increase in troponin T concentrations did not differ among cardiac surgical procedures, but the absolute troponin T concentrations did. Troponin concentrations should thus be interpreted in context of surgical procedure.
Medical subject headings
- Heart Injuries
- Heart Valve Prosthesis Implantation