Comparison of background parenchymal enhancement (BPE) on contrast-enhanced cone-beam breast CT (CE-CBBCT) and breast MRI.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 35320411.
- Also identified by DOI 10.1007/s00330-022-08699-2.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To compare the background parenchymal enhancement (BPE) levels on contrast-enhanced cone-beam breast CT (CE-CBBCT) and MRI, evaluate inter-reader reliability, and analyze the relationship between clinical factors and BPE level on CE-CBBCT. In this retrospective study, patients who underwent both CE-CBBCT and MRI were analyzed. BPE levels on CE-CBBCT and MRI were assessed by five specialists independently in random fashion, with a wash-out period of 4 weeks. Weighted kappa was used to analyze the agreement between CE-CBBCT and MRI, and intraclass correlation coefficient (ICC) was used to evaluate the inter-reader reliability for each modality. The association between BPE level on CE-CBBCT and clinical factors was evaluated by univariate and multivariate logistic regression. A total of 221 patients from January 2017 to April 2021 were enrolled. CE-CBBCT showed substantial agreement (weighted kappa = 0.690) with MRI for BPE evaluation, with good degree of inter-reader reliability on both CE-CBBCT (ICC = 0.712) and MRI (ICC = 0.757). Based on majority reports, BPE levels on CE-CBBCT were lower than MRI (p < 0.001). BPE level on CE-CBBCT was significantly associated with menstrual status (odds ratio, OR = 0.125), breast density (OR = 2.308), and previously treated breast cancer (OR = 0.052) (all p < 0.05). BPE level for premenopausal patients was associated with menstrual cycle, with lower BPE level for the 2<sup>nd</sup> week of menstrual cycle (OR = 0.246). CE-CBBCT showed substantial agreement and comparable inter-reader reliability with MRI for BPE evaluation, indicating that the corresponding BI-RADS lexicons could be used to describe BPE level on CE-CBBCT. The 2<sup>nd</sup> week of menstrual cycle timing is suggested as the optimal examination period for CE-CBBCT. • CE-CBBCT showed substantial agreement and comparable inter-reader reliability with MRI for BPE evaluation. • Menstrual status, breast density, and previously treated breast cancer were associated with the BPE level on CE-CBBCT images. • The 2<sup>nd</sup>week of the menstrual cycle is suggested as the optimal examination period for CE-CBBCT.
Medical subject headings
- Breast Neoplasms
- Mammography