Application of optimized three-dimensional digital surgical guide plates for complex midfacial fractures.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 35321792.
- Also identified by DOI 10.1016/j.injury.2022.03.014.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The treatment of midfacial fractures is always difficult. The purpose of this study was to verify whether optimized three-dimensional (3D) digital surgical guide plates combined with preformed titanium plates improved the treatment effect in complex midfacial fractures. Twenty-six patients with complex midfacial fractures were recruited and randomized into three groups: ten for Group A, eight for Group B, and eight for Group C. Group A was treated with a combination of preformed titanium plates and optimized 3D digital surgical guide plates. Group B was treated with preformed titanium plates only. Group C was treated conventionally. Clinical effects, patient-reported outcome measures (PROMs), midfacial contour, facial symmetry, surgical accuracy, △orbital volume (the absolute value of the bilateral orbital volume difference), and maximum deviation were evaluated in each of the three groups. Group A had the best postoperative clinical effects and patient-reported outcomes. Significant improvements in midfacial contour (L1[0.72±0.29 mm, P = 0.001], L2[1.04±0.46 mm, P < 0.001]), facial symmetry (S1[0.71±0.30 mm, P < 0.001], S2[0.96±0.58 mm, P < 0.001], S3[0.86±0.40 mm, P < 0.001], S5[0.81±0.16 mm, P = 0.003], S8[0.95±0.30 mm, P < 0.001], S9[1.03±0.38 mm, P < 0.001], S11[0.64±0.46 mm, P < 0.001]) and surgical accuracy (M1[R, 0.82±0.31 mm, P < 0.001], M2[R, 0.87±0.44 mm, P < 0.001], M3[L, 0.88±0.22 mm, P = 0.004], M3[R, 1.06±0.31 mm, P = 0.003], M4[L, 0.96±0.45 mm, P = 0.008], M4[R, 1.11±0.57 mm, P = 0.003], M5[R, 0.76±0.26 mm, P < 0.001], M6[L, 1.00±0.46 mm, P = 0.003], M6[R, 1.00±0.58 mm, P = 0.001], M7[0.87±0.53 mm, P = 0.001], M8[R, 0.91±0.53 mm, P < 0.001], M9[R, 0.81±0.32 mm, P = 0.010], M10[R, 1.19±0.42 mm, P = 0.009], M11[L, 0.85±0.51 mm, P = 0.021], M11[R, 0.96±0.49 mm, P = 0.003]) were found in Group A compared with the other two groups. The results of △orbital volume and maximum deviation analysis showed an ideal surgical treatment effect in Group A. Optimized 3D digital guide plates can accurately locate preformed titanium plates and effectively improve the treatment effect in complex midfacial fractures.
Medical subject headings
- Fracture Fixation, Internal
- Orbital Fractures