Feasibility of an accelerated 2D-multi-contrast knee MRI protocol using deep-learning image reconstruction: a prospective intraindividual comparison with a standard MRI protocol.

Herrmann, Judith; Keller, Gabriel; Gassenmaier, Sebastian; Nickel, Dominik; Koerzdoerfer, Gregor; Mostapha, Mahmoud; Almansour, Haidara; Afat, Saif et al. · Eur Radiol · 2022

prospective_cohort · Level II

Where this comes from

Abstract

The aim of this study was to evaluate the image quality and diagnostic performance of a deep-learning (DL)-accelerated two-dimensional (2D) turbo spin echo (TSE) MRI of the knee at 1.5 and 3 T in clinical routine in comparison to standard MRI. Sixty participants, who underwent knee MRI at 1.5 and 3 T between October/2020 and March/2021 with a protocol using standard 2D-TSE (TSE<sub>S</sub>) and DL-accelerated 2D-TSE sequences (TSE<sub>DL</sub>), were enrolled in this prospective institutional review board-approved study. Three radiologists assessed the sequences regarding structural abnormalities and evaluated the images concerning overall image quality, artifacts, noise, sharpness, subjective signal-to-noise ratio, and diagnostic confidence using a Likert scale (1-5, 5 = best). Overall image quality for TSE<sub>DL</sub> was rated to be excellent (median 5, IQR 4-5), significantly higher compared to TSE<sub>S</sub> (median 5, IQR 4 - 5, p < 0.05), showing significantly lower extents of noise and improved sharpness (p < 0.001). Inter- and intra-reader agreement was almost perfect (κ = 0.92-1.00) for the detection of internal derangement and substantial to almost perfect (κ = 0.58-0.98) for the assessment of cartilage defects. No difference was found concerning the detection of bone marrow edema and fractures. The diagnostic confidence of TSE<sub>DL</sub> was rated to be comparable to that of TSE<sub>S</sub> (median 5, IQR 5-5, p > 0.05). Time of acquisition could be reduced to 6:11 min using TSE<sub>DL</sub> compared to 11:56 min for a protocol using TSE<sub>S</sub>. TSE<sub>DL</sub> of the knee is clinically feasible, showing excellent image quality and equivalent diagnostic performance compared to TSE<sub>S</sub>, reducing the acquisition time about 50%. • Deep-learning reconstructed TSE imaging is able to almost halve the acquisition time of a three-plane knee MRI with proton density and T1-weighted images, from 11:56 min to 6:11 min at 3 T. • Deep-learning reconstructed TSE imaging of the knee provided significant improvement of noise levels (p < 0.001), providing higher image quality (p < 0.05) compared to conventional TSE imaging. • Deep-learning reconstructed TSE imaging of the knee had similar diagnostic performance for internal derangement of the knee compared to standard TSE.

Medical subject headings