Objective performance of emergency medical technicians in the use of mechanical cardiopulmonary resuscitation compared with subjective self-evaluation: a cross-sectional, simulation-based study.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 35768109.
- Also identified by DOI 10.1136/bmjopen-2022-062908 and PMC identifier 9244722.
- Licence recorded as CC BY-NC.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate the subjective and objective resuscitation performance of emergency medical technicians (EMTs) using mechanical cardiopulmonary resuscitation (MCPR) devices. This was a cross-sectional simulation-based study where participants installed the MCPR device on a training manikin. We assessed EMT-Intermediates (EMT-Is) and EMT-Paramedics (EMT-Ps) of the Emergency Medical Services (Ambulance) Division of the Taipei City Fire Department. The primary outcome was the gap between self-perceived (subjective) and actual (objective) no-flow time during resuscitation, which we hypothesised as statistically insignificant. The secondary outcome was the association between resuscitation performance and personal attributes like knowledge, attitude and self-confidence. Among 210 participants between 21 and 45 years old, only six were female. There were 144 EMT-Is and 66 EMT-Ps. During a simulated resuscitation lasting between four and a half and 5 min, EMTs had longer actual no-flow time compared with self-perceived no-flow time (subjective, 38 s; objective, 57.5 s; p value<0.001). This discrepancy could cause a 6.5% drop of the chest compression fraction in a resuscitation period of 5 min. Among the EMT personal factors, self-confidence was negatively associated with objective MCPR deployment performance (adjusted OR (aOR) 0.66, 95% CI 0.45 to 0.97, p=0.033) and objective teamwork performance (aOR 0.57, 95% CI 0.34 to 0.97, p=0.037) for EMT-Ps, whereas knowledge was positively associated with objective MCPR deployment performance (aOR 2.15, 95% CI 1.31 to 3.52, p=0.002) and objective teamwork performance (aOR 1.77, 95% CI 1.02 to 3.08, p=0.043) for EMT-Is. Moreover, regarding the self-evaluation of no-flow time, both self-satisfaction and self-abasement were associated with objectively poor teamwork performance. EMTs' subjective and objective performance was inconsistent during the MCPR simulation. Self-confidence and knowledge were personal factors associated with MCPR deployment and teamwork performance. Both self-satisfaction and self-abasement were detrimental to teamwork during resuscitation.
Medical subject headings
- Cardiopulmonary Resuscitation
- Emergency Medical Services
- Emergency Medical Technicians