Abstract
Validated software tools (Clinical Graphics [CG] and Hip<sup>2</sup>Norm) permit measurement of the percentage of femoral head coverage (%FHC), which aids in morphological classification and prediction of outcome after hip preservation surgery. (1) To assess whether acetabular parameter measurements determined from 2 commonly used software systems are comparable. (2) To determine which parameters influence the correlation or differences between software outputs and measurements. Cohort study (diagnosis); Level of evidence, 2. The study included 69 patients (90 hips) who underwent periacetabular osteotomy and had comprehensive preoperative imaging available. Lateral center-edge angle (LCEA), acetabular index (AI), and %FHC were determined using 3-dimensional computed tomography (CT) measurements by CG and Hip<sup>2</sup>Norm software. Images of 18 pelvises were segmented to determine spinopelvic parameters and subtended acetabular angles. Between-group measurements were compared using correlation coefficients and Bland-Altman analyses. The difference in the outputs of the 2 programs was defined as delta (Δ). Radiographic parameters were tested to assess whether they were responsible for differences in %FHC between software programs. Strong correlations between LCEA (ρ = 0.862) and AI (ρ = 0.825) measurements were seen between the Hip<sup>2</sup>Norm and CG programs. However, weak correlation was seen in the estimate of %FHC (ρ = 0.358), with the presence of a systematic error. Hip<sup>2</sup>Norm consistently produced lower anterior, posterior, and total %FHC values than CG. The %FHC determined by CG, but not Hip<sup>2</sup>Norm, correlated with acetabular subtended angles (<i>P</i> < .05). Pelvic tilt measured on CT did not correlate with pelvic tilt estimated by Hip<sup>2</sup>Norm (<i>P</i> = .56), and ΔPelvicTilt strongly correlated with the difference in %FHC by the 2 software programs (ρ = 0.63; <i>P</i> = .005), pelvic incidence (ρ = 0.73; <i>P</i> < .001), and pelvic tilt (ρ = -0.91; <i>P</i> < .001) as per CT. The correlation of %FHC between Hip<sup>2</sup>Norm and CG was weak (ρ = 0.358). The difference in measurements of %FHC correlated with ΔPelvicTilt. The %FHC determined by CG strongly correlated with the segmented acetabular subtended angles and thus more likely reflected true values. Hip preservation surgeons should be aware of these measurement differences because %FHC is important in the diagnosis and prognosis of acetabular dysplasia.
Medical subject headings
- Hip Dislocation
- Hip Dislocation, Congenital
Anatomy
- hip
- pelvis