Influence of reduced graphene oxide addition on kerf width in abrasive water jet machining of nanofiller added epoxy-glass fibre composite.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 35972932.
- Also identified by DOI 10.1371/journal.pone.0270505 and PMC identifier 9380911.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The present study aims to develop a novel hybrid polymer composite with reduced graphene oxide (rGO) as filler and optimize its Abrasive Water Jet Machining (AWJM) parameters for reduced kerf width. The influence of rGO addition on kerf width is analysed in detail along with Pump pressure (bar), Transverse speed (mm/min) and Standoff distance(mm). The experiments are designed based on Taguchi's orthogonal array techniques in which L27 is adopted for three input parameters at three levels. The influence of each factor is used to identify the significance of selected parameters over kerf width, and it was found that stand of distance has a major effect over kerf width irrespective of rGO %. The addition of rGO filler has a significant effect on kerf width, which decreases with the addition of rGO up to 0.2% and kerf width increases for further addition of rGO.
Medical subject headings
- Graphite
- Water